Posted by 삐꾸강아쥐쥐
SATA 채널이 4개 채널만 활성화 되어 있다.
6개의 채널을 다 활성화 시키기 위해선
환경 설정 값을 변경해 줘야 된다.
일단 F2 를 이용하여 CMOS 로 들어간다
Advanced - ATA Controller - AHCI Mode 를 Enabled 시키면
6개 채널을 다 사용 가능 해진다.
Posted by 삐꾸강아쥐쥐




,
Fortran



,
Intel



,
MKL




Trackback URL : http://n-nuri.com/trackback/443
Posted by 삐꾸강아쥐쥐




,
Server



,
Workstation



,
XVN




Trackback URL : http://n-nuri.com/trackback/423
Posted by 삐꾸강아쥐쥐




,
Server



,
SROMBSAS18E




Trackback URL : http://n-nuri.com/trackback/421
Intel SSR212MC2 의 Storeview 설치 문서 RHEL4 U4 x86 기준
Storview : http://downloadcenter.intel.com/T8Clearance.aspx?sType=&agr=N&ProductID=2816&DwnldID=13279&url=/13279/eng/storview-3.06.T049-jbi-rhel3-32-en.tar.gz&PrdMap=&strOSs=129&OSFullName=Red Hat* Enterprise Linux 4.0&lang=eng
JRE : http://java.sun.com/javase/downloads/index.jsp 에서 1.5 이상의 버전 다운로드
JRE를 설치하고 설치된 JRE 경로를 PATH 잡아준다.
java -version 으로 버전을 확인하고
Firefox 에 플러긴을 올려줘야 된다.
cd /usr/lib/firefox/plugins
ln -s $jre_path/plugin/i386/ns7/libjavaplugin_oji.so
ls 로 해당 링크 확인
Storview 설치
tar xvzf storview-$version.tar.gz 압축을 푼다.
./StorviewInstall
[##_Gallery|1393124553.jpg||width="400" height="300"_##]
Posted by 삐꾸강아쥐쥐




,
SSR212MC2



,
Storview




Trackback URL : http://n-nuri.com/trackback/405
Posted by 삐꾸강아쥐쥐




,
Server



,
SSR212MC2



,
Storage




Trackback URL : http://n-nuri.com/trackback/397
Posted by 삐꾸강아쥐쥐




,
Intel



,
SBCEGBSW10



,
Server




Trackback URL : http://n-nuri.com/trackback/373
Posted by 삐꾸강아쥐쥐




,
Performance



,
Raid




Trackback URL : http://n-nuri.com/trackback/360
Posted by 삐꾸강아쥐쥐




,
Performance



,
Raid



,
Raid5




Trackback URL : http://n-nuri.com/trackback/358
| The Intel® RAID controller Write Back cache policy can be enabled on a logical drive basis when a RAID controller cache battery backup module (BBU) is installed. The BBU will hold data in cache for a period of time in the case of a power interruption and then complete the data write to hard disk once power is returned. The amount of time the battery will hold data in cache is dependent on the controller memory and battery configuration; please check the specifications for the BBU solution being used. If the Write Back setting is enabled in Intel® RAID BIOS Console 2 or Intel® RAID Web Console 2, the logical drive Write Back cache option will be temporarily set to Write Through during a battery recharge in order to protect data in the case of a power interruption during the charge cycle, then automatically returned to Write Back when the battery is fully charged. When doing I/O performance tests, the performance test may show lower performance when the BBU is charging because of the temporary Write Through cache setting. For better performance metrics, please wait for the battery to be fully charged when the cache setting will be reset to Write Back for the logical drive. |
Posted by 삐꾸강아쥐쥐




,
Intel



,
Raid



,
Write Back